Compare a loaded resistor divider with a Norton current source and parallel resistance. Both networks deliver the same load voltage and current.

Circuit notes

Norton's Theorem

A linear two-terminal network can be replaced by a current source in parallel with a resistance. The upper circuit is the original loaded divider. The lower circuit is its Norton equivalent. Both loads are 1 kΩ and read 2 V, 2 mA.

Find the equivalent

Imagine removing RL1 and shorting the output terminals. R2 is bypassed by the short, so all short-circuit current comes through R1. Deactivate the independent voltage source by replacing it with a short to find the resistance seen at the output.

IN=6 V1 kΩ=6 mARN=R1∥R2=500 Ω\begin{aligned} I_N&=\frac{6\,\mathrm V}{1\,\mathrm{k}\Omega}=6\,\mathrm{mA}\\ R_N&=R_1\parallel R_2=500\,\Omega \end{aligned}

IN points upward and injects 6 mA into the parallel RN/RL2 network. RN is the equivalent resistance, not an extra series load. Each comparison network has its own visible ground reference.

Compare the loaded results

IL=INRNRN+RL=2 mAVL=ILRL=2 VVopen=INRN=3 V\begin{aligned} I_L&=I_N\frac{R_N}{R_N+R_L}=2\,\mathrm{mA}\\ V_L&=I_LR_L=2\,\mathrm V\\ V_{\mathrm{open}}&=I_NR_N=3\,\mathrm V \end{aligned}
  • Vorig — green: original output voltage.
  • Veq — red: Norton output voltage.
  • Iorig — blue: original load current.
  • Ieq — purple: Norton load current.

The source supplies 6 mA, while the load receives 2 mA and RN receives 4 mA. Terminal equivalence does not imply equal internal currents or equal internal power.

Observe in CircuitSim

The example opens with DC operating point, a compact results table, and notes. Both voltage rows should read 2 V and both current rows 2 mA. There is no time chart because these are steady results.

Try two loads

Change both RL1 and RL2 → Resistance so the external loads remain identical, then run:

  1. Set both loads to 500 Ω. Both outputs become 1.5 V and 3 mA.
  2. Set both loads to 2 kΩ. Both outputs become 2.4 V and 1.2 mA.

Restore both loads to 1 kΩ afterward. Changing V1, R1 or R2 requires recalculating IN and RN; the lower network is an explicit equivalent, not an automatically updating component.

Model assumptions

Sources and resistors are ideal and linear. Deactivate independent sources when finding equivalent resistance; circuits containing dependent sources generally require a test source. The terminal equivalence applies to the specified port and does not preserve internal power dissipation.