Skip to main content

Band-Pass Filter

CI

CircuitSim

·

Created Oct 3, 2026

·

Updated Oct 3, 2026

Preview will appear once the owner saves the schematic
Details

Components

4


Schematic

Yes


Simulation

AC sweep


Copies

Not copied yet

About this circuit

Use a series RLC circuit to pass a band around resonance. Measure the output across the resistor and explore bandwidth.

Circuit notes

Band-Pass Filter

Use a series RLC circuit to pass a band around resonance. Measure the output across the resistor and explore bandwidth.

Schematic and stimulus

V1 on the left supplies an AC analysis magnitude of 1 V and phase of 0°. L1 (10 mH) and C1 (1 µF) form the series path across the top. R1 (100 Ω) returns the output to ground; Vout measures its voltage.

Vin is green, Vout is red and Iin is blue. Current is positive from the source into the network.

Expected response

With s=j2πfs=j2\pi f and H=Vout/VinH=V_{\mathrm{out}}/V_{\mathrm{in}}:

H(s)=RR+sL+1/(sC)H(s)=\frac{R}{R+sL+1/(sC)}

At resonance the inductor and capacitor reactances cancel. The total impedance is R1, so Vout reaches 1 V (0 dB), phase crosses 0° and current reaches 10 mA. Low and high frequencies are attenuated.

f0=12πLC=1.5915 kHzf_0=\frac{1}{2\pi\sqrt{LC}}=1.5915\,\mathrm{kHz} Q=L/CR=1Q=\frac{\sqrt{L/C}}{R}=1 Δf=R2πL=1.5915 kHz\Delta f=\frac{R}{2\pi L}=1.5915\,\mathrm{kHz}

The −3 dB passband edges are approximately 983.63 Hz and 2.5752 kHz. Bandwidth is the difference between those edges.

Read the Bode chart

The saved AC sweep runs from 100 Hz to 10 kHz, with 100 points per decade. Voltage magnitude and phase are shown separately. Current is hidden from the default chart to keep the voltage-gain scale readable; enable Iin in the chart series controls and expand the magnitude-axis range to plot it. Open Table for all 201 frequency samples and the same probe order. Because the input is 1 V, output voltage in dBV has the same numeric value as voltage gain in dB. Current magnitude is in dBA referenced to 1 A, so it is not a voltage gain.

GdB=20log⁡10∣H∣,ϕ=arg⁡(H)G_{\mathrm{dB}}=20\log_{10}|H|,\qquad \phi=\arg(H)

AC sweep computes a sinusoidal steady state at every frequency; it does not show startup. AC analysis magnitude and AC analysis phase control this sweep. The source's Frequency and Peak voltage properties apply to transient simulation instead.

Try two changes

  1. Change C1 → Capacitance from 1u to 2u. Run again: the center moves to 1.1254 kHz. Restore 1u.
  2. Change R1 → Resistance from 100 to 200. Run again: the center stays at 1.5915 kHz, while the passband widens and Q falls to 0.5. Restore 100.

Click Run simulation after each change. Keep V1's AC analysis magnitude at 1 and phase at 0, then restore all component values above to return to the saved response.

Model limits

The source, resistor, capacitor and inductor models are ideal. Probes draw no current. Source impedance, component tolerance, parasitic resistance/capacitance and external loading are omitted; these can shift cutoff and reduce rejection.

Components used

Components used
4 components
NameManufacturerMPNCountType

AC Voltage Source

Generic

—

1

Official

Capacitor

Generic

—

1

Official

Inductor

Generic

—

1

Official

Resistor

Generic

—

1

Official

Try this circuit yourself

Free to get started. No download — runs in your browser with a full SPICE engine.