Phase-Shift Oscillator Filter
CircuitSim
·
Created Oct 3, 2026
·
Updated Oct 3, 2026
Details
Components
4
Schematic
Yes
Simulation
Transient analysis
Copies
Not copied yet
About this circuit
Inspect the attenuation and phase shift of the loaded three-section RC network used in a phase-shift oscillator.
Circuit notes
Phase-Shift Oscillator Filter
Inspect the attenuation and phase shift of the loaded three-section RC network used in a phase-shift oscillator.
V1 drives three cascaded high-pass RC sections, each using 10 nF and 10 kΩ. The sections load one another; they are not independent buffered filters. A1 buffers the last node so the 10 kΩ output load does not change that network.
At 650 Hz the output is approximately 34.5 mV peak and nearly inverted relative to the 1 V peak input. Use the table or voltage-axis zoom to examine the smaller red waveform. This explains the phase and gain requirements of the related oscillator.
Read the results. The saved transient chart uses separate voltage and current panels; the table provides numerical samples. The first voltage probe is green and the second red. The first current probe is blue; a second current probe is purple.
Model limits. The three-terminal op-amp model has implicit ±12 V output limits, 200,000 low-frequency gain and 10 MHz gain-bandwidth product. Supply pins are intentionally absent in this functional model. In Schmitt-trigger and relaxation/integrator oscillator examples, the switching amplifier uses a 100 kHz gain-bandwidth setting to resolve transitions cleanly at the saved time step. It omits detailed slew-rate, input common-mode, output-current and thermal limits.
Try it. Set V1 frequency to 1300 Hz; the filter has less attenuation and a different phase shift. Restore the original values after comparing the results.