Termination of a Transmission Line
CircuitSim
·
Created Oct 3, 2026
·
Updated Oct 3, 2026
Details
Components
3
Schematic
Yes
Simulation
Transient analysis
Copies
Not copied yet
About this circuit
Compare matched, nearly open, and low-resistance loads to see the sign and size of reflected pulses.
Circuit notes
Termination of a Transmission Line
Compare matched, nearly open, and low-resistance loads to see the sign and size of reflected pulses.
Circuit operation
V1 launches a 1 V pulse into the 50 Ω line. The saved 50 Ω load produces no reflection. Change only RL to compare the two mismatch experiments.
Expected behavior
An approximately open load reaches 2 V; a 1 Ω load reaches about 39 mV. The reflected change arrives back at the input 40 ns after launch. The 50 Ω source absorbs it, so there is no endless train of reflections.
Reading the results
The first voltage probe is green and the second is red. Current probes start with blue. The schematic opens fitted to its extents. The transient runs for 400 ns with a maximum step of 0.2 ns. Compare sending and receiving waveforms with time-axis cursors. The table uses the same probe order.
Try a change
Set RL to 1 GΩ, approximating an open circuit. The load voltage doubles and the reflected pulse is positive.
Set RL to 1 Ω. The reflected pulse is negative and the load voltage is small. Restore the saved values after comparison.
Model limits
Each line is ideal and lossless: Z0 and TD are independent of frequency. Conductor and dielectric loss, dispersion, radiation, connectors, and breakdown are omitted. Line length is represented by propagation delay; the drawing is not a physical length scale. These examples describe differential line voltage relative to the shared return conductor.
References: Single-stub matching, distributed filter principles.