Impedance Matching (Shunt Stub)
CircuitSim
·
Created Oct 3, 2026
·
Updated Oct 3, 2026
Details
Components
3
Schematic
Yes
Simulation
Transient analysis
Copies
Not copied yet
About this circuit
A shorted shunt stub cancels the reactive part of a transformed load admittance.
Circuit notes
Impedance Matching (Shunt Stub)
A shorted shunt stub cancels the reactive part of a transformed load admittance.
Circuit operation
The main 50 Ω line transforms a 100 Ω load over a 6.08174 ns delay. A second 50 Ω line with the same delay is shorted at its far end and connected in shunt at the input.
Expected behavior
At 25 MHz the normalized admittances add to 1, giving a 50 Ω real input. Expect about 1 V peak at the input and √2 V peak across the 100 Ω load. The stub stores and returns energy; its average real power is zero in this lossless model.
Reading the results
The first voltage probe is green and the second is red. Current probes start with blue. The schematic opens fitted to its extents. The transient runs for 400 ns with a maximum step of 0.2 ns. Compare sending and receiving waveforms with time-axis cursors. The table uses the same probe order.
Try a change
Set STUB delay to 3 ns. Its susceptance no longer cancels the load-line susceptance at 25 MHz. Restore the saved values after comparison.
Model limits
Each line is ideal and lossless: Z0 and TD are independent of frequency. Conductor and dielectric loss, dispersion, radiation, connectors, and breakdown are omitted. Line length is represented by propagation delay; the drawing is not a physical length scale. These examples describe differential line voltage relative to the shared return conductor.
References: Single-stub matching, distributed filter principles.