AD620 Instrumentation Amplifier Bridge Sensor Instrumentation Amplifier
CircuitSim
·
Created May 24, 2026
·
Updated Jun 30, 2026
Details
Components
1
Schematic
Yes
Simulation
DC operating point
Copies
Not copied yet
About this circuit
A bridge-sensor front end with a left-to-right DC source row, shared ground rail, external gain resistor, and measured single-ended output.
Circuit notes
Bridge Sensor Instrumentation Amplifier
Application
This circuit shows the AD620 used as a bridge-sensor front end. Two low-level bridge sense nodes feed the differential inputs, and the amplifier converts the small differential signal into a single-ended output that can be read by the operating-point table.
Schematic
VCC, VIN+, VIN-, and VEE are arranged as a left-to-right source row. All source returns, the AD620 REF pin, and RLOAD return join the same bottom ground rail so the reference point is visible and unambiguous.
Design Context
VIN+ is set to 110 mV and VIN- is set to 100 mV, representing a 10 mV bridge imbalance with about 105 mV common-mode voltage. The split +/-15 V rails give the macro-model ample headroom for this small-signal operating point.
RG is 49.9 kOhm. For an AD620-style instrumentation amplifier, the nominal gain is approximately 1 + 49.4 kOhm / RG, or about 2 V/V here. With REF tied to ground, the expected output is therefore roughly 20 mV for the 10 mV differential input.
Expected Behavior
The table should show Vin+ slightly higher than Vin-, and Vout should be a small positive voltage near twice the differential input. Because this is a DC operating-point demo, the result is a steady-state value rather than a waveform.
Key Values
- VCC / VEE: +15 V and -15 V.
- Bridge inputs: 110 mV and 100 mV.
- RG: 49.9 kOhm, setting about 2 V/V gain.
- RLOAD: 10 kOhm.
Suggested Experiments
- Increase VIN+ by a few millivolts and confirm that Vout rises by roughly twice that input change.
- Change RG to 10 kOhm for a higher-gain bridge interface.
- Move REF to a nonzero reference voltage to see how the output baseline shifts without changing the input difference.
Featured Component
U1 is the AD620 instrumentation amplifier. IN+ and IN- sense the bridge differential voltage, RG sets the gain, REF defines the output baseline, and OUT drives the measured load.
Components used
Components used
1 component
Try this circuit yourself